Applies to:Sun StorageTek SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsCAP, status failed, Error needed hardware not available for audit 1,1,5,2,0 capSL3000 library, new install, error during Self Diagnostic Test Failure message displayed on SL Console Gui: "Cap Motion Test Failed ERROR: Needed hardware not available for audit 1,1,5,2,0 cap" Able to unlock/lock and open the CAP from SL console without any problems.CauseDiagnostic self test bug.SolutionThe Self Test Cap Diagnostic error is a library microcode error resolved in the latest release at 3.0:-Changes to cap avoidance logic caused a reservation race condition with self test's invocation of the audit command. Self test then would fail to reserve the necessary robot for auditing which is required as last step in 'closing' the cap door. Recommendation to resolve the "needed hardware not available for audit" error message is to upgrade the SL3000 code to 3.0. Information to this KB was created from Tape Hardware Community Page. Attachments This solution has no attachment |
||||||||||||
|