Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1321684.1 : SL3000 - Auto Clean Option Missing in FRS-3.0 non-Partitioned Library
In this Document
Applies to:Sun StorageTek SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsAuto Clean Option Missing in FRS-3.0 non-Partitioned Library.The check box in the configuration screen in SLConsole that enables Auto Cleaning is missing for a non-Partitioned library using FRS-3.0 code. CauseFirmware change.SolutionThe screen should look like the image in the attached file:There is one recommended workaround to enable Auto Cleaning if the check box is missing: a). Use the CLI to enable Auto Clean for Partition "0" (as this is a non-Partitioned library) using the following command:Note! The Auto Clean feature setting DOES NOT get brought into FRS-3.0 from lower levels of microcode. If the feature is enabled in 2.x code, it will be disabled after a FRS-3.0 code upgrade. In addition, any interface reconfigurations between FC/SCSI and HLI will return this setting to the default value of "disabled". Attachments This solution has no attachment |
||||||||||||
|