Solution Type  Problem Resolution Sure

Solution  1320556.1 :   VSM - Channel Card Reporting FSC32C0 Parity Errors  


Related Items
  • Sun StorageTek VSM System
  •  
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Symptoms
  Cause
  Solution


Created from <SR 3-3572010301>

Applies to:

Sun StorageTek VSM System - Version: 4 and later   [Release: 4.0 and later ]
Sun StorageTek VSM System - Version: 4 to 5C   [Release: 4.0 to 5.0]
Information in this document applies to any platform.

Symptoms


Customer reporting SIM messages with FSC32C0 embedded FSC 32C0 in the message.
Example:
.SLS6659I VTSS VTSS1 SIM:5090100000008FE0329080009E001A104200105C000032C00510420110068012
SLS6974I FAULT REPORTED BY VTSS:VTSS1 MODEL:VSMx SERIAL:xxxxxxxx FSC:32C0 FRU:xxx
Note Sense Bytes 22 & 23 are 32C0.

Cause


Defective channel card


#define FSC32C0_OM_ESCON_CIP_MEM_PAR_CHK 0x32C0


CSE: @SAME
ENG: An ICE CIP memory parity check 2 error was detected.
This error occurs when the CIP reads one of its memory
locations and bad parity is present on the data word.

Solution


Connect to VSM and acquire a set of base files.
Place files on zenobia
Run the crunch_it all.
Review the files and look for FSC 32C0 and identify card type, location, part number.
Create FS for local to replace defective channel card