In this Document Created from <SR 3-3572010301>
Applies to:Sun StorageTek VSM System - Version: 4Sun StorageTek VSM System - Version: 4 to 5C [Release: 4.0 to 5.0] Information in this document applies to any platform. SymptomsCustomer reporting SIM messages with FSC32C0 embedded FSC 32C0 in the message. Example: .SLS6659I VTSS VTSS1 SIM:5090100000008FE0329080009E001A104200105C000032C00510420110068012 SLS6974I FAULT REPORTED BY VTSS:VTSS1 MODEL:VSMx SERIAL:xxxxxxxx FSC:32C0 FRU:xxx Note Sense Bytes 22 & 23 are 32C0. CauseDefective channel card #define FSC32C0_OM_ESCON_CIP_MEM_PAR_CHK 0x32C0 CSE: @SAME ENG: An ICE CIP memory parity check 2 error was detected. This error occurs when the CIP reads one of its memory locations and bad parity is present on the data word. SolutionConnect to VSM and acquire a set of base files. Place files on zenobia Run the crunch_it all. Review the files and look for FSC 32C0 and identify card type, location, part number. Create FS for local to replace defective channel card Attachments This solution has no attachment |
||||||||||||
|