Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1319418.1 : SL8500 - CAP Auto mode SLS2259A problem
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsCAP Auto mode SLS2259A problem.(Cartridge Access Port) Sun StorageTek SL8500 Modular Library System - Version: 6.0x code Information in this document applies to HSC connected libraries. CauseDownlevel PTFs with 6.01 through 6.04 microcode.SolutionPTFs for HSC CAP Auto Mode Issue are Now Available - The HSC PTFs that are required along with SPS-6.05 to fix the CAP Auto mode SLS2259A problem are now posted on the Internal Support Portal ( https://support.us.oracle.com ). This problem can occur in FRS-6.01 through SPS-6.04 codes. Below is a synopsis from one of the PTFs.An SLS2259A message can be displayed when ejecting cartridgesThe PTFs and new patch numbers are provided below: 6.2 - L1H16B1(VM), - Not yet posted Attachments This solution has no attachment |
||||||||||||
|