Solution Type Problem Resolution Sure Solution 1317231.1 : Sun SPARC[TM] Enterprise M3000: Incorrect Software Setting Prior to Shipping Certain M3000 Servers May Cause Unexpected Behavior.
Oracle Confidential (PARTNER). Do not distribute to customers Reason: internal info only Created from <SR 3-3282728501>
Applies to:Sun SPARC Enterprise M3000 Server - Version: Not ApplicableInformation in this document applies to any platform. SymptomsDue to incorrect software settings prior to shipping on certain Sun SPARC Enterprise M3000 servers the following issues will be seen:
When typing the keyboard sequence <tab><tab> at the XSCF prompt with the current user in "Normal" mode. This sequence will display a list of all available commands. If the command "enablecodboard" is present in the list, the described issue has been experienced. CauseThis issue can occur on the following platforms:
PPMYYWWSSS SolutionThe resolution to this issue is to open a service request for an escalation mode password, and follow the procedures:For a new unconfigured xscf use procedures located at: https://support.us.oracle.com/oip/faces/secure/km/DocumentDisplay.jspx?id=1313741.1 References<NOTE:1313741.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000 - How to correct an invalid or wrong brandid setting on a configured XSCFU.<NOTE:1313793.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000 - How to correct an invalid or wrong brandid setting on a new xscfu. Attachments This solution has no attachment |
||||||||||||
|