Solution Type Problem Resolution Sure Solution 1315689.1 : Sun Enterprise[TM] 10000: WARNING: ring ID YXXXXXXX not found
Applies to:Sun Enterprise 10000 Server - Version: Not ApplicableInformation in this document applies to any platform. SymptomsAfter installing a system board autoconfig reports "WARNING: ring ID YXXXXXXX not found" example: % autoconfig sysboard14 CauseThe messages can be read as "I'm detecting part XXXXXXX, revision Y which I know nothing about. So, I'm assuming it's functionally like part XXXXXXX rev Z, which I do have in my database."In the above example, revision 1 of 1910149 is unknown to autoconfig, but revision 0 is known, so revision 0 will be used. SolutionThe messages are warnings and not failures, so if the board passes hpost at level 16 or higher, bring the domain up and then sort out the warning message.Items to check on are: