Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1307172.1 : T10000 - FSC6109 After Loading Firmware on a 1.x KMS Platform
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version: Not ApplicableOracle Key Manager - Version: 1.2.0 and later [Release: 1.0 and later] Information in this document applies to any platform. SymptomsGetting error 6109 in the drive after a firmware upgrade.FSC6109 - This drive does not contain the key needed to decrypt this tape. The ID of the missing key can be viewed from this drive using the VOP program. The ID has also been written to the Operational Key Token (OKT). Connect the OKT to the Key Management Station (KMS) and view the error log for error 6109. ChangesUpgraded drive firmware.CauseCannot get keys from the OKT.SolutionBuild an EKT token that has the failing drive in it and re-enroll the drive.Attachments This solution has no attachment |
||||||||||||
|