Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1307172.1
Update Date:2011-03-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1307172.1 :   T10000 - FSC6109 After Loading Firmware on a 1.x KMS Platform  


Related Items
  • Sun StorageTek T10000 Tape Drive
  •  
  • Oracle Key Manager
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Drives - T10000
  •  




In this Document
  Symptoms
  Changes
  Cause
  Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version: Not Applicable and later   [Release: N/A and later ]
Oracle Key Manager - Version: 1.2.0 and later    [Release: 1.0 and later]
Information in this document applies to any platform.

Symptoms

Getting error 6109 in the drive after a firmware upgrade.
FSC6109
- This drive does not contain the key needed to decrypt this tape.
The ID of the missing key can be viewed from this drive using the VOP program.
The ID has also been written to the Operational Key Token (OKT).
Connect the OKT to the Key Management Station (KMS) and view the error log for error 6109.

Changes

Upgraded drive firmware.

Cause

Cannot get keys from the OKT.

Solution

Build an EKT token that has the failing drive in it and re-enroll the drive.
Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.