Solution Type  Problem Resolution Sure

Solution  1298998.1 :   VTL: Compression Data Consistency Check / Invalid data signature found  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Virtual Tape Software
  •  




In this Document
  Symptoms
  Cause
  Solution


Created from <SR 3-2946310441>

Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
Information in this document applies to any platform.

Symptoms

While reading a Virtual Tape (VTape) the following error is seen: Compression Data Consistency Check : Invalid data signature found

Cause

There is the possibility of multiple causes for this error to be seen:

1) A hard drive failed in the array at or near the time of the read request
2) There was a momentary data path error that failed to supply the requested read.
3) There is previous data corruption on the VTape usually caused by an unexpected outage to the disk array with Write Cache Mirroring turned off.


Solution

In each case an SR needs to be opened to Oracle Support to have the Open Systems Disk to analyze the AllSupportData from the disk array.

Depending on the output from the Disk Support Team follow the actions below:

1) If a failed drive has occurred, then put in a request to have the drive replaced.
2) If no drive has failed, then re-drive the read request from the backup application
3) If the error does not occur again, then item 2 above applies and no action is necessary.
4) If the error does appear again, then we will need to do a dump of the meta-data and possibly a full tape dump as well to find out if there is indeed data corruption.  Please open an support ticket to VTL Support for the Instructions and Utilities.

Note: The Get Well Plan was issued to for each respective version of VTL to relieve issues with VTape corruption do to Write Cache Mirroring. It is HIGHLY recommended that all VTL's be upgraded to the Get Well Plan.  Please contact VTL Support for patches.