Solution Type Problem Resolution Sure Solution 1298506.1 : SL8500 - LSMs Go Offline With SSD in Redundant Electronics Configuration Under ACSLS
In this Document
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsLSMs Go Offline With SSD in RE Configuration.(Service Safety Door) (Redundant Electronics) CauseOpening the main door while using the Service Safety Door will cause the LSMs to go offline in Redundant Electronics configurations connected to ACSLS.SolutionThe workarounds at this time are either:a). Disconnect the ethernet cables on the standby HBC card prior to safety door activity, orFinal fix will be in future release of code beyond 6.04. @ CR-7020025 Attachments This solution has no attachment |
||||||||||||
|