Solution Type Problem Resolution Sure Solution 1287213.1 : Sp:Fault.Security.Integrity-Compromised
In this Document Created from <SR 3-2821383707>
Applies to:Exadata Database Machine V2 - Version: Not Applicable to Not Applicable - Release: N/A to N/AOracle Exadata Storage Server Software - Version: 11.2.1.2.0 to 11.2.2.2.0 [Release: 11.2 to 11.2] Linux x86-64 SymptomsAfter Powering down an Exadata cell or compute node alerts are raised of log entries created like:SP shows failure. SP:fault.security.integrity-compromised ChangesChanging hardware components (e.g. flash cards)CauseIf the AC power is not removed from the chassis before replacing te components then the ILOM (which is not powered down by the front panel power switch) will detect the removal of the lid and flag an intrusion detection fault.The disconnection of AC power to the chassis is a mandatory action in the Sun field engineering instructions. It doesn't always happen SolutionThis message occurs when the chassis cover has been removed while AC is still attached to the chassis.From the ilom: The fault can be cleared with -> start /SP/faultmgmt/shell fmadm> fmadm repair /SYS/SP Also you can use: cellcli> list alerthistory to check the whole status. Attachments This solution has no attachment |
||||||||||||
|