Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1214656.1
Update Date:2010-09-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  1214656.1 :   Sun Storage 7000 Unified Storage System: NDMP SCSI Tape performance degradation  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
  Symptoms
  Cause
  Solution
  References


Applies to:

Sun Storage 7110 Unified Storage System - Version: Not Applicable and later   [Release: NA and later ]
Sun Storage 7210 Unified Storage System - Version: Not Applicable and later    [Release: NA and later]
Sun Storage 7310 Unified Storage System - Version: Not Applicable and later    [Release: NA and later]
Sun Storage 7410 Unified Storage System - Version: Not Applicable and later    [Release: NA and later]
Information in this document applies to any platform.

Symptoms

If your hardware includes SCSI tape connected to the Sun 7000 unified storage and if you are running the software version 2010.Q1.0.*, you will experience a slow tape read or write performance, and thus the backup and restore may be slower as well.

Use the following steps to check.

BUI  Status/NDMP can tell you the inquiry strings of the library/tape drive, so you know the make/model.

Also, you can check BUI Maintenence/Hardware to find out if you have a FC card or a SCSI card in the chassis.

BUI Analytics provides NDMP Bytes/Sec transferred to/from Tape, can show you the tape performance. If the tape performance is around 2mbps then you are hitting this issue.




Cause

This is due to a software bug.
<SUNBUG: 6932154>

Solution

The above bug has been fixed in 2010.Q1.1.0 software release, a software upgrade to the latest released is required to resolve this issue.

References

<BUG:6932154> - WCREG14:ADD MEMBER NOTIFICATION- UNABLE TO ADD COMMENTS

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.