Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1208953.1 : Sun Storage 7000 Unified Storage System: An unanticipated system error occurred:
In this Document
Applies to:Sun Storage 7110 Unified Storage System - Version: Not ApplicableSun Storage 7210 Unified Storage System - Version: Not Applicable and later [Release: NA and later] Sun Storage 7310 Unified Storage System - Version: Not Applicable and later [Release: NA and later] Sun Storage 7410 Unified Storage System - Version: Not Applicable and later [Release: NA and later] Information in this document applies to any platform. SymptomsBUI or aksh cli operation might fail with the following errorUnanticipated error or software defect CauseThis is due to one of the bugs listed below, to identify the relevant bug id match the function-name in the error message.< < < SolutionUpgrade the software if your bug status is fixed released. Otherwise you need to file a support Service Request (SR) for this issue.Internal only: Workaround: Check if you can reduce content that was being read and the error occurred, or .. Increase the akd/rpc_rmax size value. `svccfg -s akd setprop akd/rpc_rmax = '<value>'` but has performance implications. If customer is hitting a new function and is not in the above list, file a RPE CR and update this KA. Attachments This solution has no attachment |
||||||||||||
|