Solution Type  Problem Resolution Sure

Solution  1181543.1 :   SL3000 - Base Module FAN Failure: Upper Fan Module From Electronics Module Stops Working Intermittently  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  




In this Document
  Symptoms
  Cause
  Solution


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Customer would not be doing the work around as this is for the CSE to do.

Applies to:

Sun Storage SL3000 Modular Library System - Version: Not Applicable and later   [Release: NA and later ]
Information in this document applies to any platform.

Symptoms

Short description:

Upper fan module in the SL3000 fan tray may stop at some time by it self, and turn on the fault led. By moving/adjusting the fan tray, it may start spinning again. Moving it again might stop it.. And so on. Fan tray replacement hasn't fixed the problem so far.

Cause

Known tolerance issue with fan tray connector in the SL3000.


Solution

Issue is open with the Quality Engineering Group and is pending resolution.
It is a tolerance stack up issue; it will probably end up as a redesign.

Work Around:
In the interim; release the cable tie by the fan tray connector and re-seat the cable.

Note:
Solution will be updated when a final fix is available.