Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1181543.1 : SL3000 - Base Module FAN Failure: Upper Fan Module From Electronics Module Stops Working Intermittently
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun Storage SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsShort description: Upper fan module in the SL3000 fan tray may stop at some time by it self, and turn on the fault led. By moving/adjusting the fan tray, it may start spinning again. Moving it again might stop it.. And so on. Fan tray replacement hasn't fixed the problem so far. CauseKnown tolerance issue with fan tray connector in the SL3000.SolutionIssue is open with the Quality Engineering Group and is pending resolution.It is a tolerance stack up issue; it will probably end up as a redesign. Work Around: In the interim; release the cable tie by the fan tray connector and re-seat the cable. Note: Solution will be updated when a final fix is available. Attachments This solution has no attachment |
||||||||||||
|