Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1132935.1
Update Date:2010-06-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  1132935.1 :   VTL - Failover wizard fails reporting 3 targets but only 2 initiators  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Value System
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Symptoms
  Cause
  Solution


Applies to:

Sun Storage VTL Prime System - Version: Not Applicable and later   [Release: NA and later ]
Sun Storage VTL Plus Storage Appliance - Version: Not Applicable and later    [Release: NA and later]
Sun Storage VTL Storage Appliance - Version: Not Applicable and later    [Release: NA and later]
Sun Storage VTL Value System - Version: Not Applicable and later    [Release: NA and later]
Information in this document applies to any platform.

Symptoms

Failover wizard reports 3 targets, but only 2 initiators

Cause

Failover wizard reports 3 targets, but only 2 initiators

Solution

1. A rescan sometimes clears the devices (even though the clients are zoned and OS can see them, the SAN clients are not defined to VTL, so VTL should not pick them up).

2. If rescan does not help, a reboot also sometimes clears the devices.

3. If reboot doesn't help, deactivate client host zoning, so VTL server cannot discover them, and rescan devices in VTL console

4. If zoning changes are not possible, ipstor.conf file can be modified to remove the WWN of the discovered devices (FalconStor engineering should be engaged to perform this modification).