Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1132935.1 : VTL - Failover wizard fails reporting 3 targets but only 2 initiators
In this Document
Applies to:Sun Storage VTL Prime System - Version: Not ApplicableSun Storage VTL Plus Storage Appliance - Version: Not Applicable and later [Release: NA and later] Sun Storage VTL Storage Appliance - Version: Not Applicable and later [Release: NA and later] Sun Storage VTL Value System - Version: Not Applicable and later [Release: NA and later] Information in this document applies to any platform. SymptomsFailover wizard reports 3 targets, but only 2 initiatorsCauseFailover wizard reports 3 targets, but only 2 initiatorsSolution1. A rescan sometimes clears the devices (even though the clients are zoned and OS can see them, the SAN clients are not defined to VTL, so VTL should not pick them up).2. If rescan does not help, a reboot also sometimes clears the devices. 3. If reboot doesn't help, deactivate client host zoning, so VTL server cannot discover them, and rescan devices in VTL console 4. If zoning changes are not possible, ipstor.conf file can be modified to remove the WWN of the discovered devices (FalconStor engineering should be engaged to perform this modification). Attachments This solution has no attachment |
||||||||||||
|