Solution Type  Problem Resolution Sure

Solution  1132727.1 :   VTL - V40z server will not boot - Unexpected trap in boot loader  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Symptoms
  Changes
  Cause
  Solution


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 and later   [Release: 1.0 and later ]
Information in this document applies to any platform.

Symptoms

VTL server will not boot
Getting error message
Message: Unexpected trap in boot loader

Changes

N/A

Cause

N/A

Solution

Recreate the boot_archive by booting in failsafe mode and running "bootadm update-archive -R /a". The procedure to do this can be found in Doc ID 1018947.1

Document can be viewed or downloaded from http://www.oracle.com/technetwork/documentation/index.html.

Additional Information
Corrupted boot_archive
VTL
V40z
Flash archive


Attachments