Solution Type Problem Resolution Sure Solution 1098659.1 : SL8500 - PTP Initialization Errors After Upgrading Code to 4.73
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun Storage SL8500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsPTP initialization errors after code upgradePass thru Port will not initialize FSC5017 Error 5017 ChangesSL8500 firmware 4.73 was installed.CauseSL8500 firmware 4.73 made change to the servo profile of the PTP; increased the current to the PTP sled to provide more margin moving in the channel. With this change, if the long PTP belt is not tensioned correctly, it can cause it to slip on the belt pulley. The belt tension cannot be adjusted in the field and the PTP must be replaced.SolutionWork Around:Engineering has come up with a procedure to tension the belt. Refer to the attached document: SL8500 PTP Belt Tightening Procedure The fix for this issue will be a correction in next release in SL8500 firmware. Until that time, the work around should be used to reduce the number of PTPs that would be replaced in the field. Attachments This solution has no attachment |
||||||||||||
|