Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1020981.1 : Tape - CommVault Does Not See STK Libraries in Windows 2003 in the Device Manager When Attached to an Emulex 8gig HBA
PreviouslyPublishedAs 268468
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L700 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek SL500 Modular Library System - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek SL3000 Modular Library System - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 9-May-2011. SymptomsCommVault does not see STK libraries in Windows 2003 in the device manger when attached to an Emulex 8 gig HBA.Consider the following scenario:
STATUS_INVALID_DEVICE_REQUEST Changes{CHANGE}Cause{CAUSE}SolutionResolutionMicrosoft Hotfix KB943545 Error returned by the IOCTL_SCSI_GET_INQUIRY_DATA operation on a Windows Server 2003-based computer: "STATUS_INVALID_DEVICE_REQUEST Detailed information is located at the fix below: Hotfix KB943545 This fix has been tested and verified in the Oracle/Sun lab. Additional Information Any of Sun's libraries connected with MS Server 2003, Emulex 8GB HBA, and Comm Vault 8.0 would see this issue. Backup app: CommVault 8.0 OS : Windows 2003 64 bit. HBA: HP branded Emulex card 8 gig (aj763a/ah403a) Driver 7.2.20.006 FW 1.00A12 Library: L700 Commvault 8.0, Windows 2003 Win2k3, Microsoft hotfix KB943545, HBA Emulex 8 gig, L700, L180, SL500, SL3000, SL8500, STATUS_INVALID_DEVICE_REQUEST Attachments This solution has no attachment |
||||||||||||
|