Solution Type  Problem Resolution Sure

Solution  1020676.1 :   2500 and 6000 Arrays Show 0MB Cache Memory Size  


Related Items
  • Sun Storage 6540 Array
  •  
  • LSI SANtricity Storage Manager
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 6580 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
  • Sun Storage Flexline 380 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Modular Disk Device Software
  •  

PreviouslyPublishedAs
262728


Symptoms
If the Controller Summary page in Sun StorageTek[TM] Common Array Manager(CAM) displays 0MB of Cache memory this indicates that you are experiencing Change Request: 6756414 for 2500 Series Arrays, or 6747153 for 6000 Arrays.
  • 2500 Series Arrays with firmware release 07.35.10.10 and Common Array Manager 6.2.0 through 6.4.0
  • 6000 Arrays with 07.15.11.10 firmware and Common Array Manager 6.2.0 through 6.4.0
  • 6000 Arrays with 07.15.11.10 firmware and SANtricity Storage Manager 10.30
  • 0MB value for Cache Memory displays when you select Physical Devices--> Controllers in CAM.
  • sscs list -a array_name controller shows 0MB value for Controller Cache Memory

ArrayFirmwareBUI Showssscs CLI shows
250007.35.04.100MB0MB
251006.70.54.11340MB340MB
600007.15.07.100MB0MB
600006.60.11.10811MB811MB


SAMPLE SSCS OUTPUT:

# /opt/SUNWstkcam/bin/sscs list array st6000 |grep "Firmware"
Firmware Version: 07.15.11.12
#
# /opt/SUNWstkcam/bin/sscs list -a st6000 controller |egrep "Controller|Cache"
Controller: A
ID: Tray.85.Controller.A
Cache Memory Size: 0MB
Controller: B
ID: Tray.85.Controller.B
Cache Memory Size: 0MB
#


Resolution
This is a superficial problem and does not indicate a hardware fault or performance problem with your array. The resolution is to upgrade CAM and your array firmware.
These Change Requests have been resolved in 
  • 2500 firmware 07.35.44.10 or later
  • 6000 07.50.08.10 or later
  • CAM 6.4.1 or later(the firmware above is bundled as such)
  • SANtricity Storage Manager 10.50 or later for 6000 Arrays(the firmware is on the CD image)
The latest version of CAM and array firmware can be found at:
http://www.sun.com/storage/management_software/resource_management/cam/get_it.jsp

The latest version of SANtricity Storage Manager can be requested at:
https://www2.sun.de/dct/forms/reg_us_1508_643_0.jsp

 
NOTE:  2500 controllers (for 2540, 2530 or 2510 arrays) can either be populated with
512MB cache DIMM's or 1GB cache DIMM's. During DIMM or Controller replacement,
verify the cache size, either through CAM or by visual inspection of the DIMM
(only 1 GB DIMM's will have a label indicating PN 540-7736) before ordering a
replacement component. The DIMM Sizes are listed under Storage Array->Array Name->FRU


Product
Sun StorageTek 2510 Array
Sun StorageTek 2530 Array
Sun StorageTek 2540 Array
Sun StorageTek 6140 Array
Sun StorageTek 6540 Array
Sun Storage 6780 Array
Sun Storage 6580 Array
Sun StorageTek Flexline 380 Array
Sun StorageTek FlexLine 300 Series Storage Systems
Sun StorageTek Common Array Manager Software 6.2
Sun StorageTek Common Array Manager Software 6.4
SANtricity Storage Manager

Cache,0MB, memory, CAM, 6140, 6540, 6580, 6780, 2540, 2530, 2510, 6000, 2500

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback