Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1020595.1
Update Date:2011-02-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1020595.1 :   ACSLS - Error response from library handler, LH_E RR_REQUEST_INVALID during configuration of SL3000  


Related Items
  • Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS)
  •  
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
261328


Applies to:

Sun StorageTek SL3000 Modular Library System
Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version: 7.0 and later    [Release: 7.0 and later]
All Platforms
Checked for relevance on 3-Feb-2011.

Symptoms

Error messages generated when running acsss_config for a non-partitioned library:

(Note: This problem can also happen when running 'config acs new'. )
/export/home/ACSSS/config/in_lib_conf: Error response from library handler, LH_ERR_REQUEST_INVALID

/export/home/ACSSS/config/in_lib_conf: Cannot establish library communications

2150 E Cm_ProcessResponses.C 1  1155
Lh error: Cm_4400::ProcessAck: ACS 0 configured to ACSLS with partition ID = 0, but the library is NOT partitioned.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
The host interface on the SL3000 library was set to non-partitioned SCSI and should be non-partitioned HLI (host LMU interface).



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback