Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1020584.1
Update Date:2009-10-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  1020584.1 :   POST fails on 6120/6920/6320 array configuration with "Vcc Differential mode test failed"  


Related Items
  • Sun Storage 6320 System
  •  
  • Sun Storage 6120 Array
  •  
  • Sun Storage 6920 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
261188


Symptoms
Issue Presents Itself with the following symptoms:
  • Controller has gone to fault-disabled or ready-disabled
  • Controller has been replaced
At this point:

1) Attach a serial connection to the faulted controller
2) Issue "enable uN" to place the controller online, and observe the serial connection.
3) The POST will fail with the message.

---------------------------------------------------

6120-2
Starting POST
..Vcc differential mode test failed.
......
POST end Press C to continue

--------------------------------------------------------

After manual intervention controller continues to boot.


Resolution
Resolution requires replacement of BOTH PCU in the tray with the faulted controller.

 



Product
Sun StorageTek 6320 System
Sun StorageTek 6120 Array
Sun StorageTek 6120/6320 Controller Firmware 3.2
Sun StorageTek 6920 System

Internal Comments
The document has been created in preview of solution that took place under SR # 70944272 .
In this case we had 6920 and array 10, 2x4 array (u3 controller) was error'd with this condition.


Sun Storage 6120,6920,6320.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback