Solution Type Problem Resolution Sure Solution 1020584.1 : POST fails on 6120/6920/6320 array configuration with "Vcc Differential mode test failed"
PreviouslyPublishedAs 261188 Symptoms Issue Presents Itself with the following symptoms:
1) Attach a serial connection to the faulted controller 2) Issue "enable uN" to place the controller online, and observe the serial connection. 3) The POST will fail with the message. --------------------------------------------------- 6120-2 Starting POST ..Vcc differential mode test failed. ...... POST end Press C to continue -------------------------------------------------------- After manual intervention controller continues to boot. Resolution Resolution requires replacement of BOTH PCU in the tray with the faulted controller.
Product Sun StorageTek 6320 System Sun StorageTek 6120 Array Sun StorageTek 6120/6320 Controller Firmware 3.2 Sun StorageTek 6920 System Internal Comments The document has been created in preview of solution that took place under SR # 70944272 . In this case we had 6920 and array 10, 2x4 array (u3 controller) was error'd with this condition. Sun Storage 6120,6920,6320. Attachments This solution has no attachment |
||||||||||||
|