Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1020245.1 : L700/L180/HP LTO - Drives Do Not Display "Busy" on Library Op Panel When Reading/Writing to the Drive
PreviouslyPublishedAs 254808
Applies to:Sun StorageTek L700 Tape LibrarySun StorageTek L700e Tape Library LTO Tape Drive - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 27-Jan-2011. SymptomsHP LTO drives do not display "busy" on the Library Op Panel when reading or writing to the drive.ChangesFirmware updated.CauseThis bug was reported to have been fixed in 3.18.02 library code but due to a compiler malfunction, the SCN was not merged into the code.SolutionResolutionL700 SPS code 3.18.31 has been created with the actual fix. This fix will be integrated into the next level code release. Contact Tape Hardware Support should you need the SPS code. This is done by opening a ticket via MOS. Product Sun StorageTek LTO FC for L700/L180 StorageTek L700e Tape Library Sun StorageTek L700 Tape Library Bug ID: 6673315 HP LTO, Busy not displayed on Op Panel, L700, L700e, L180, 3.18.31, 3.18.02, Read to drive, Write to drive Attachments This solution has no attachment |
||||||||||||
|