Solution Type Problem Resolution Sure Solution 1020195.1 : eeprom command causes panic due to a spelling error of the parameter .
PreviouslyPublishedAs 253989 Symptoms When misspelling the value of the parameter of eeprom command such as "eeprom auto-boot?=flase" ( instead of "false" ), a the following panic reboot might occur. panic[cpu0]/thread=30003ad0d60: bad stack overflow at TL 2 %tl %tpc %tnpc %tstate %tt 1 000000000101b958 000000000101b95c 0000001606 068 %ccr: 00 %asi: 00 %cwp: 6 %pstate: 16<PEF,PRIV,IE> 2 00000000010073dc 00000000010073e0 9100001507 068 %ccr: 91 %asi: 00 %cwp: 7 %pstate: 15<PEF,PRIV,AG> %g0-3: 0000000000000000 000000000000000a 000000123eb40b30 000000123eb40b30 %g4-7: 0000000015080a0d 0000000000000002 000000000180e580 0000000000000068 Register window 7, caller callback_handler+20 : : * This panic can occur even after one typo. * This panic can occur on any sun4u system with OBP revision older than 4.27. (not include 4.27) Resolution Upgrade OBP revision later than 4.27 . Relief/Workaround * use OBP command instead of eeprom command or * don't misspell the value of the parameter of eeprom command Product Sun Fire V215 Server Sun Fire V245 Server Internal Comments This document is based on CR 6750765. This CR ( 6750765 ) is a duplicate of CR 6510676. Currently, only patch 140685-01 for V215 / V245 has been released, there is no plan to release for other platforms. Received the following comments form engineering. 6510676 was fixed 2 years ago (Feb 2007) and first became available in OBP 4.27. Looking at the OBP/POST Platform Patch Summary page http://re.west/SunWeb/Patches/obp/index.html , it looks like Seattle's previous release was based on 4.25. The jump from 4.25 to 4.30 (which inherited any fixes at the 4.27 level) would have involved a sizable list of CR's. However, what is clearly true is that moving from 4.25 to 4.30 involved getting the fix for 6510676. Most pre-CMT platforms are at or near EOL, so no new qualifications are planned. But, for any platforms operating at an OBP revision older than 4.27, the solution is to get a release on anything 4.27 or higher. Unless there is a customer request, there is no plan to make obp releases for other non-CMT platforms just to get the fix for CR 6510676. Attachments This solution has no attachment |
||||||||||||
|