Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1019755.1 : VSM - The VTCS Display VTSS command shows a VTSS is Online-P
PreviouslyPublishedAs 245186
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms SymptomsDisplay VTSS command shows the VTSS is Online-pQuery VTSS shows online pending (Online-p) when displaying from one or most hosts. Other hosts may show the VTSS is Online. VT QU VTSS shows n/a for Capacity, DBU and VTV Count. State shows Online-p VT QU VTSS shows state is Online-p VTCS fully initializes before HSC comes up to FULL service level Message "SLS6654I VTCS Main Task Waiting for work" appears in log before "SLS1505I HSC service level FULL initialization complete" SLS6630I ORPHAN COPY OF VTV VVVVVV IN OFFLINE VTSS XXXXXXXX SLS6675E VTSS:XXXXXXXX VTD:DDDDDD CONFIGURATION ERROR RC=RRRRRRRR SUBSYSTEM INFO:ZZZZZ1/ZZZZZ2/ZZZZZ3 IOS002A devn NO PATHS AVAILABLE CausePossible DAC (data assurance check) on the VTSSSolutionUse the following steps:1. Ask Sun StorageTek VTSS support to remotely dial in to the VTSS to verify there is no DAC condition on the VTSS box. For further information on the DAC condition see 1016471.1 2. If no DAC conditions exist, vary all of the VTDs offline to MVS, and vary the VTSS offline from the host that is showing the online-pending condition. 3. Vary the VTSS online and vary the VTDs online. 4. Run the AUDIT VTSS utility for the affected VTSS. For information regarding what the status ONLINE-P indicates see 1017264.1 Attachments This solution has no attachment |
||||||||||||
|