Solution Type  Problem Resolution Sure

Solution  1019746.1 :   T10000 - Dismount Errors for T10KB Cleaning Media in SL3000 and SL8500  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek Host Software Component (HSC) for MVS and z/OS
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Mainframe Software
  •  

PreviouslyPublishedAs
245048


Applies to:

Sun StorageTek SL3000 Modular Library System
Sun StorageTek SL8500 Modular Library System
Sun StorageTek Host Software Component (HSC) for MVS and z/OS - Version: 6.2 and later    [Release: 6.0 and later]
IBM z/OS on System z
Checked for relevance on 7-Dec-2010.

Symptoms

Error messages are received for T10KB cleaning cartridge dismount
 =SLS0923I DRIVE 880D HAS BEEN CLEANED USING CLN058
46 =SLS0107D DISMOUNT OF CLN058 FROM DRIVE 880D - DRIVE HAS LOADED
CARTRIDGE; REPLY DISMOUNT, RETRY, OR IGNORE (D/R/I)
 R 46,D
 IEE600I REPLY TO 46 IS;D
 =SLS0662I LMU RESPONSE ERROR - 00,000,18,00
 =SLS0698I REQ ACS 00 SEQ 02/550 REQ C  DISMOUNT    VOL CLN058 SRC  01/01:07:00 DRV 880D TGT 01/02:02:00 CEL
 =SLS0699I RESPONSE ACS 00 SEQ 02/550 ERR 10/02 DRIVE IS NOT OPERATIONAL RET'D TO SRC LSM 01
*=SLS0117E DISMOUNT OF CLN058 FROM DRIVE 880D - LMU ERROR 65156515 ACS 00
 =SLS0080I MOUNT OF INV240 ON DRIVE 880D - VOLUME AT 00:01:08:03:00
 =SLS0662I LMU RESPONSE ERROR - 00,000,18,00
 =SLS0698I REQ ACS 00 SEQ 02/551 REQ B  MOUNT       VOL INV240 SRC  01/08:03:00 CEL      TGT 01/01:07:00 DRV 880D
 =SLS0699I RESPONSE ACS 00 SEQ 02/551 ERR 04/05 DRIVE IS FULL RET'D TO SRC LSM 01
 =SLS0130I DRIVE 880D FOUND FULL WHILE ATTEMPTING MOUNT OF INV240
*=SLS0867E ATTEMPTING TO LOCATE ERRANT VOLUME CLN058
 =SLS0873I ERRANT RECOVERY OF CLN058 - VOLUME AT DRIVE 880D
*47 =SLS0869D ERRANT RECOVERY OF CLN058 - DRIVE 880D IS LOADED; REPLY  RETRY, IGNORE, OR DISMOUNT (R/I/D)

Cause

For T10KB cleaning cartridges only, the library (SL3000 or SL8500) sends a Mount Response to HSC before the clean action has completed.   This results in HSC attempting to dismount the cleaning cartridge before the cleaning cartridge has been unloaded.

Solution

Contact Oracle Corp and open a case to report the problem to Tape Library Hardware Support.

To contact Oracle Support, please view https://support.oracle.com/CSP/ui/flash.html


Internal Comments
See FAB 242446
HSC, T10KB, T10000B, cleaning cartridge, SL8500, SL3000, dismount, robot