Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1019670.1 : SL3000 - New Install, Dual Hand Bots will not Initialize
PreviouslyPublishedAs 243406 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL3000 Modular Library SystemAll Platforms Checked for relevance on 9-Feb-2011. SymptomsLibrary will not initializeError 3215 robot initialization error Error 3104 invalid set of Frame labels 2008-10-07T14:42:18.475 1,1,0,1,0 root default internal 0 trace 3952 From device Data= ChangesAdditional InformationInformation of new install Library initializes and works with just 1 robot installed. The correct license has been installed to support 2 robots. The configuration is 1 base module and 2 CEMs, one on each side. The panel labels have been changed to support 2 robots. Refer to attached file for complete init sequence showing fault. Cause{CAUSE}SolutionResolutionInstall the 2nd robot to the left of the 1st robot to resolve initialization problem. The first time we installed the 2nd bot on the right side of the 1st bot and we got the error. Then we installed the bot on the left side of the 1st bot and it came up ok. @ SL3000, Initialization failure, Library will not initialize, Dual hand bot library, Invalid frame labels, New install Attachments This solution has no attachment |
||||||||||||
|