Solution Type  Problem Resolution Sure

Solution  1019637.1 :   KMS - KMS Fails to Boot With Exit Status of 95  


Related Items
  • Oracle Key Manager
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Encryption KMS
  •  

PreviouslyPublishedAs
242726


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Oracle Key Manager - Version: 1.1.0 and later   [Release: 1.0 and later ]
All Platforms
Checked for relevance on 10-Feb-2011.

Symptoms

Improper shut down can corrupt the Boot archive.
power failure can corrupt the boot-archive.
Error on boot c:/method/boot-archive “failed with exit status 95.
Error95

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
To correct the problem:

The terminal window, will ask you to log into maintenance mode.  Use the root user and password (stkEAL33)
At command prompt enter> svcadm clear system/boot-archive
Hit enter,
Then reboot.
This should clear the problem, and the KMS should now boot normally.