Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1019615.1 : L700 - Library Will Not initalize, FSC30AC, FSC3088
PreviouslyPublishedAs 242287
Applies to:Sun StorageTek L700 Tape LibraryAll Platforms Checked for relevance on 18-Jan-2011. SymptomsSymptomsLibrary fails initialization FSC3088 FSC30AC Library will not come up FSC3201 Changes{CHANGE}CauseDefective Coil Cable.SolutionResolutionReplaced Coil Theta Cable, PN3102643xx Multiple parts were swapped out previously. Reach safe errors were being reported with the init failure. These failures were typically associated with downlevel hand assemblies where the LEDs were dimming. This could be intermittent and would tend to go away after the hand warmed up. Must make sure that the hand is about 318 level and the firmware is 3.xx or above. 3102643XX - CABLE ASSY, COIL, THETA..page 23 in the L700 ILLUSTRATED PARTS CATALOG Additional Information Further details of problem This library had been intermittent problems prior to failing solid. It had been at the account for over three years. Was originally running 3.07 code and was moved up to 3.14 with no change in problem. FSC3201 was also showing up in the error log. 3201 FSC30AC, FSC3088, FSC3201, L700, Library will not initialize, Fails to init, Coil Theta Cable, Reach safe error Attachments This solution has no attachment |
||||||||||||
|