Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1019615.1
Update Date:2011-01-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1019615.1 :   L700 - Library Will Not initalize, FSC30AC, FSC3088  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
242287


Applies to:

Sun StorageTek L700 Tape Library
All Platforms
Checked for relevance on 18-Jan-2011.

Symptoms

Symptoms
Library fails initialization
FSC3088
FSC30AC
Library will not come up
FSC3201

Changes

{CHANGE}

Cause

Defective Coil Cable.

Solution

Resolution
Replaced Coil Theta Cable, PN3102643xx
Multiple parts were swapped out previously.   Reach safe errors were being reported with the init failure.  These failures were typically associated with downlevel hand assemblies where the LEDs were dimming.  This could be intermittent and would tend to go away after the hand warmed up.  Must make sure that the hand is about 318 level and the firmware is 3.xx or above.

3102643XX - CABLE ASSY, COIL, THETA..page 23 in the L700 ILLUSTRATED PARTS CATALOG


Additional Information
Further details of problem
This library had been intermittent problems prior to failing solid.  It had been at the account for over three years.  Was originally running 3.07 code and was moved up to 3.14 with no change in problem.  FSC3201 was also showing up in the error log.

3201
ERR_CMO_FAILED_REACH_RETRACT,
Reach failed to successfully retract to a safe position.
FRU: LOCATION: CONFIDENCE %:
HAND ASSY LSM 85
Z flex cable LSM 10
MPC LCU 5

SEVERITY - error

3088
ERR_SRV_EXCESSIVE_TACH_PHASE_ERRORS,
An excessive amount of tachometer phase errors was detected
Refer to specific FRU callouts for mechanism indicated
Check robotic cabling connections and condition.
Check z flex cabling connections and condition.
FRU: LOCATION: CONFIDENCE %:
---> If MECH = Theta<---
THETA MTR/ENC. ASSY LSM 75
MPC LCU 15
Z Flex Cable LSM 10
---> If MECH = Z<---
Z MTR/ENC. ASSY LSM 75
MPC LCU 15
Z Flex Cable LSM 10
---> If MECH = HAND<---
HAND ASSY LSM 65
MPC LCU 15
Flex Cable LSM 10

SEVERITY - error

30ac
ERR_SRV_MINIMUM_INIT_MOVE_NOT_DETECTED,
During initialization for the mechanism indicated, the software did
not detect a change in the tach counter near the beginning of the
move and has assumed the tach is not functioning.
Check for any obstructions and for cables properly connected, then
proceed with FRU replacements.
FRU: LOCATION: CONFIDENCE %:
---> If MECH = Theta<---
MPC LCU 50
THETA MTR/ENC. ASSY LSM 30
Theta Flex Cable LSM 20
---> If MECH = Z<---
MPC LCU 50
Z MTR/ENC. ASSY LSM 30
Z Flex Cable LSM 20
---> If MECH = HAND<---
MPC LCU 50
HAND ASSY LSM 30
Z Flex Cable LSM 20

SEVERITY - error





FSC30AC, FSC3088, FSC3201, L700, Library will not initialize, Fails to init, Coil Theta Cable, Reach safe error



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.