Solution Type Problem Resolution Sure Solution 1019226.1 : Sun Fire V210, V240: DIMMs that have the same Manufacturer's Part Number but different JEDEC ID codes
PreviouslyPublishedAs 237284
Applies to:Sun Fire V210 Server - Version: Not ApplicableSun Fire V240 Server - Version: Not Applicable and later [Release: NA and later] All Platforms SymptomsSymptomsSystem can not boot automatically when "auto-boot?" is set to true. Available for this topic, a Video Tutorial; Brief how-to video tutorials that provide step-by-step instructions answering Sun's most frequently asked questions. View the video answer and/or follow the detailed instructions below. Sunsolve users must download the attachment to view the video. Changes{CHANGE}CauseThis problem is due to using a pair of DIMMs that have the same Manufacturer's Part Number but different JEDEC ID codes programmed in the SPD data.This error does not remove the memory from use but it does stop the system from booting automatically when "auto-boot?" is set to true. SolutionResolutionThis issue is fixed with OBP 4.22.23 or later OBP 4.22.23 is contained in patch 121683-04 Relief/Workaround There is no workaround, the only fix is to have OBP at 4.22.23 or higher. Internal Comments Change History Date: 2009-11-25 User Name: Anthony Rulli Action: updated Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team Product_uuid dc751a7c-eece-4157-8e4e-376351aa49fa 18d48708-5867-11d6-8128-c95a9ce59853 Attachments This solution has no attachment |
||||||||||||
|