Solution Type Problem Resolution Sure Solution 1019051.1 : SL8500 - Pass Thru Port Initialization Failures
PreviouslyPublishedAs 233801
Applies to:Sun Storage SL8500 Modular Library SystemAll Platforms SymptomsIf the PTP is not able to trip both sensors during initialization, the PTP module will not come ready.Cause
SolutionResolutionTo resolve the issue, remove the PTP assembly, and adjust the sensors so that when the PTP is extended the sensor is tripped on the side the array is extended towards. The sensors can be found on the underside of the PTP assembly. Product Sun StorageTek StreamLine SL8500 SL8500, Pass Thru Port, PTP, Sensors, 5017 Internal Comments Oracle review 11/09/09. Attachments This solution has no attachment |
||||||||||||
|