230462


Symptoms
A new Sun Cluster[TM] 3.x installation used a JBOD unit (in this case, a Sun StorEdge[TM] D2 array in a split mode) for its shared storage.
After the installation and testing of the cluster, some problems with the shared array were discovered. The problem occurred when a node was booted into cluster, causing many SCSI warnings and a volume managment problem on the other node. In this case, the metadevices needed maintenance. The errors did not occur if the node was booted outside of the cluster.

Symptoms:

On the Node Being booted:
Dec  4 12:15:04 nodeA pseudo: [ID 129642 kern.info] pseudo-device: tod0
Dec  4 12:15:04 nodeA genunix: [ID 936769 kern.info] tod0 is /pseudo/tod@0
Dec  4 12:15:04 nodeA pseudo: [ID 129642 kern.info] pseudo-device: pm0
Dec  4 12:15:04 nodeA genunix: [ID 936769 kern.info] pm0 is /pseudo/pm@0
Dec  4 12:15:04 nodeA syslogd: going down on signal 15
Dec  4 12:15:04 nodeA xntpd[224]: [ID 866926 daemon.notice] xntpd exiting on signal 15
Dec  4 12:15:26 nodeA genunix: [ID 672855 kern.notice] syncing file systems...
Dec  4 12:15:26 nodeA genunix: [ID 904073 kern.notice]  done
Dec  4 12:16:40 nodeA genunix: [ID 540533 kern.notice] ^MSunOS Release 5.8 Version Generic_108528-16 64-bit
Dec  4 12:16:40 nodeA genunix: [ID 913631 kern.notice] Copyright 1983-2001 Sun Microsystems, Inc.  All rights reserved.
Dec  4 12:16:40 nodeA genunix: [ID 678236 kern.info] Ethernet address = 0:3:ba:17:f8:6e
SCSI Errors on NodeB:
Dec  4 12:15:34 nodeB eri: [ID 517527 kern.info] SUNW,eri0 : 100 Mbps full duplex link up
Dec  4 12:16:10 nodeB scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus2):
Dec  4 12:16:10 nodeB        Received unexpected SCSI Reset
Dec  4 12:16:15 nodeB scsi: [ID 107833 kern.warning] WARNING: /pci@8,700000/pci@2/scsi@4 (qus0):
Dec  4 12:16:15 nodeB        Received unexpected SCSI Reset
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4/sd@8,0 (sd82):
Dec  4 12:16:19 nodeB        Error for Command: write                   Error Level: Retryable
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.notice]  Requested Block: 67                        Error Block: 67
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.notice]  Vendor: FUJITSU                            Serial Number: 0228X67457
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.notice]  Sense Key: Aborted Command
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.notice]  ASC: 0x47 (scsi parity error), ASCQ: 0x0, FRU: 0x0
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus2):
Dec  4 12:16:19 nodeB        Target synch. rate reduced. tgt 8 lun 0
Dec  4 12:16:19 nodeB scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4/sd@9,0 (sd83):
Dec  4 12:16:19 nodeB        Error for Command: write                   Error Level: Retryable


Resolution
Steps for Resolution

Change the scsi-initiator-id on one node to 6 globally for all devices at the OBP level and then use the nvramrc script to set the scsi-initiator-id to 7 on the local devices.

You can find the complete procedure in the Sun Cluster 3.x With SCSI JBOD Storage Device Manual for Solaris OS under 1.  Installing a SCSI JBOD Storage Device, Installing a Storage Array, How to Install a Storage Array

See bugs: BugID: 4663904 , BugID: 4670376 , BugID: 4669448   



Product
Sun StorageTek D2 Array
Sun Cluster 3.0

Sun Cluster 3.1, Sun Cluster 3.0, D2, array, scsi errors, scsi, jbod, scsi-initiator-id, cluster