Solution Type  Problem Resolution Sure

Solution  1018643.1 :   Sun Enterpise[TM] 3500 Server - How to Replace a Disk Under Solstice Disksuite  


Related Items
  • Sun Enterprise 3500 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
230342


Symptoms
The Sun Enterprise[TM] 3500 server (E3500) is a special case when replacing internal disks that are under Solstice Disksuite.
The E3500 has dual ported FC-AL drives, making it similar to the Sun StorEdge[TM] A5x00 array. This procedure should be used for the following:
  • Replacing a simple data disk
  • Replacing a mirrored disk under Solstice disksuite control
The procedures are all individually explained in various documents for the A5x00, and Solstice Disksuite related documents. The purpose of this document is to bring these procedures together in one document for FC-AL disks in the E3500 enclosure.

Resolution
Procedures:
REPLACING A SIMPLE DATA DISK

1. Ensure the following patches are installed:
  • Solaris[TM] 9      Luxadm patch - 113049-01 or higher
  • Solaris[TM] 8     Luxadm patch - 109529-06 or higher
  • Solaris[TM] 7     IB & Luxadm patch - 107473-07 or higher
  • Solaris 2.6           sf/socal/ib/luxadm patch - 105375-10 or higher &  ssd patch - 105356-08 or higher
  • Solaris[TM] 2.5.1     sf/socal/ib/luxadm patch - 105310-08 or higher & ssd patch - 104708-16 or higher
    These provide support for the luxadm commands on the E3500.

2. Unmount the disk and then stop it with the command

    luxadm stop <logical path or physical path or WWN ...>

3. Remove the device entries, the following command will complete this

    luxadm remove_device <logical path or physical path or WWN ...>

4. Replace the disk, then

    luxadm insert  <no arguments required>                        

  This will recreate the device entries, the device is now ready to be used.

 
REPLACING A MIRRORED DISK UNDER Solstice Disksuite CONTROL

1. Ensure the following patches are installed:
  • Solaris 9    Luxadm patch - 113049-01 or higher
  • Solaris 8     Luxadm patch - 109529-06 or higher                 
  • Solaris 7     IB & Luxadm patch - 107473-07 or higher
  • Solaris 2.6     sf/socal/ib/luxadm patch - 105375-10 or higher & ssd patch - 105356-08 or higher
  • Solaris 2.5.1   sf/socal/ib/luxadm patch - 105310-08 or higher &  ssd patch - 104708-16 or higher
   These provide support for the luxadm commands on the E3500.

2. Remove any metadb's located on this failed HD

3. Remove the device entries, the following command will complete this

    luxadm remove_device <logical path or physical path or WWN ...>

4. Replace the disk, then

    luxadm insert  <no arguments required>
    or  
    luxadm insert_device <logical path or physical path or WWN ...>


5. Recreate the partition table with format (use an exact copy of this part table as its mirrored HD)

6. Recreate the metadb's on this new HD with

    metadb -a -c <number copies> <device eg c0t0d0s7>

7. Invoke metareplace -e <submirror> <device eg c0t0d0s0> <new device> to sync all submirrors in needs maintenance mode

8. verify sync with   metastat | grep %

Product
Sun Enterprise 3500 Server

upgrade, upgrading, recovery, recover, configure, configured, configuration, SDS, LVM
Previously Published As
79673

Change History
Date: 2009-11-20
User Name: Josh Freeman
Action: Updated
Comment: Minor formatting changes - Document barely relevant anymore. Might be time to archive next go round if no more hits. ESG Content Team update.
Date: 2004-12-20
User Name: 71396
Action: Approved
Comment: Performed final review on document.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback