Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1018621.1 : fwutil gives error: "no such file or directory" when upgrading firmware on Sun StorEdge[TM] A1000's or Sun StorEdge[TM] A3x00's
PreviouslyPublishedAs 230317 Symptoms fwutil gives error: "no such file or directory" when upgrading firmware on Sun StorEdge[TM] A1000's or Sun StorEdge[TM] A3x00's. However you can see the firmware file in the gui as well as in /usr/lib/osa/fw. Resolution This may be due to components in the array that are not optimal. Run healthck -a to verify the array status. If components are failed or are in any other state besides optimal then you must first fix the components and then you will be able to upgrade the firmware. Product SPARCstorage RSM Array 2000 Sun StorageTek A1000 Array Sun StorageTek A3500 Array Sun StorageTek A3000 firmware, upgrade, fw, rm6, raid manager Previously Published As 79277 Change History Date: 2004-11-28 User Name: 71396 Action: Approved Comment: Reviewed doc, updated product names and trademarking, publishing. Version: 3 Date: 2004-11-23 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2004-11-23 User Name: 88218 Action: Approved Comment: Document is correct Version: 0 Date: 2004-11-23 User Name: 88218 Action: Accept Comment: Version: 0 Date: 2004-11-20 User Name: 126242 Action: Approved Comment: . Version: 0 Date: 2004-11-20 User Name: 126242 Action: Created Comment: Version: 0 Product_uuid e5da84f6-356a-11d7-9770-8237f2dd1528|SPARCstorage RSM Array 2000 2a792916-0a18-11d6-8d0a-c3d03933af3c|Sun StorageTek A1000 Array 2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array 2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000 Attachments This solution has no attachment |
||||||||||||
|