Solution Type  Problem Resolution Sure

Solution  1018621.1 :   fwutil gives error: "no such file or directory" when upgrading firmware on Sun StorEdge[TM] A1000's or Sun StorEdge[TM] A3x00's  


Related Items
  • Sun SPARCstorage RSM Array 2000
  •  
  • Sun Storage A3000 Array
  •  
  • Sun Storage A1000 Array
  •  
  • Sun Storage A3500 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
230317


Symptoms
fwutil gives error: "no such file or directory" when upgrading firmware on Sun StorEdge[TM] A1000's or Sun StorEdge[TM] A3x00's. However you can see the firmware file in the gui as well as in /usr/lib/osa/fw.

Resolution
This may be due to components in the array that are not optimal. Run healthck -a to verify the array status. If components are failed or are in any other state besides optimal then you must first fix the components and then you will be able to upgrade the firmware.

Product
SPARCstorage RSM Array 2000
Sun StorageTek A1000 Array
Sun StorageTek A3500 Array
Sun StorageTek A3000

firmware, upgrade, fw, rm6, raid manager
Previously Published As
79277

Change History
Date: 2004-11-28
User Name: 71396
Action: Approved
Comment: Reviewed doc, updated product names and trademarking, publishing.
Version: 3
Date: 2004-11-23
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2004-11-23
User Name: 88218
Action: Approved
Comment: Document is correct
Version: 0
Date: 2004-11-23
User Name: 88218
Action: Accept
Comment:
Version: 0
Date: 2004-11-20
User Name: 126242
Action: Approved
Comment: .
Version: 0
Date: 2004-11-20
User Name: 126242
Action: Created
Comment:
Version: 0
Product_uuid
e5da84f6-356a-11d7-9770-8237f2dd1528|SPARCstorage RSM Array 2000
2a792916-0a18-11d6-8d0a-c3d03933af3c|Sun StorageTek A1000 Array
2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array
2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback