Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1018383.1 : L20/L40/L80/L180/L700 - Service Required Light On - Library Fails to Initialize
PreviouslyPublishedAs 229895
Applies to:Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later]Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L20 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L40 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 26-Dec-2010. SymptomsService required light is onInitialization failed Initialization failed message from library panel Blank screen after pressing MENU button Changes{CHANGE}Cause{CAUSE}SolutionResolutionUse the following steps to resolve problem: 1. Check the FSC logs to help determine the error 2. Check location of hand assembly for possible robotics Initialization problem 3. Attempt to re-IPL the library with a Power ON Reset 4. Check cable connections to MPC and MPB 5. Replace MPC or MPB as required L700, L180, L20, L40, L80, Customer, commented, system board was recently replaced, Library is getting power, L40/80 libraries use LLC cards for Electronic Module Previously Published As STKKB20591 Attachments This solution has no attachment |
||||||||||||
|