Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1018248.1
Update Date:2009-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1018248.1 :   Sun StorEdge[TM] 3960/6960: Invalid WWN error during zone creation using command line interface  


Related Items
  • Sun Storage 6960 Array
  •  
  • Sun Storage 3960 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
229645


Symptoms

During zone creation using command line interface, the createvezone command returns invalid WWN error.

For example:

msp0: root# /opt/SUNWsecfg/bin/createvezone -n v1 -c I00001 -w 210000e08b05f055 -z hom001_a_v1 -a hom001_a_i9
ERROR: Invalid WWN 210000e08b05f055 on v1 initiator I00001, or unavailable. 

You have already checked the WWN number and it seems to be correct.



Resolution

The characters that are part of the WWN number need to be typed using capital letters.
In our example, the correct WWN number should be 210000E08B05F055



Product
Sun StorageTek 3960
Sun StorageTek 6960

indy, 6960, 3960, createvezone, Invalid WWN
Previously Published As
81071

Change History
Date: 2006-07-26
User Name: 71396
Action: Add Comment
Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=81071 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. ***
Version: 0
Date: 2005-04-01
User Name: 25440
Action: Approved
Comment: Added product to title. Audience changed to contract per FvF http://kmo.central/howto/FvF.html
Publishing.
Version: 3
Date: 2005-04-01
User Name: 25440
Action: Accept
Comment:
Version: 0
Date: 2005-03-31
User Name: 29482
Action: Approved
Comment: I think this is a good idea. I ran across the same problem in the past and it cost me somw extended troubleshooting time.
Version: 0
Date: 2005-03-31
User Name: 29482
Action: Accept
Comment:
Version: 0
Date: 2005-03-31
User Name: 130207
Action: Approved
Comment: I decided to create this doc after I had had this issue on a customer environment. The resolution is simple and I believe the doc will be helpful.

I'm forwarding the doc to the Tech Review..

Thanks

Valdir
Version: 0
Date: 2005-03-31
User Name: 130207
Action: Created
Comment:
Version: 0