Solution Type Problem Resolution Sure Solution 1018235.1 : VTL Plus - Failover not working with AIX client
PreviouslyPublishedAs 229625 Symptoms Failover not working NBU cannot rediscover virtual devices after failover Resolution Fix provided in VTL Plus Build 1323. Additional Information VTL Plus Symantec NetBackup (NBU) VTL failover works with virtual WWPNs moving (spoofed) between nodes for failover, but AIX uses SCSI ids for the robotics and the SCSI ids change when failover occurs causing a manual reconfigure of the devices to be necessary. IBM AIX NBU can rediscover devices after failback See Radiance case #65525285 Product VTL Plus Previously Published As STKKB80549 Product_uuid 75b7684c-9057-11db-9e93-080020a9ed93 Attachments This solution has no attachment |
||||||||||||
|