Solution  1018235.1 :   VTL Plus - Failover not working with AIX client  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
229625


Symptoms
Failover not working
NBU cannot rediscover virtual devices after failover

Resolution
Fix provided in VTL Plus Build 1323.



Additional Information
VTL Plus
Symantec NetBackup (NBU)
VTL failover works with virtual WWPNs moving (spoofed) between nodes for failover, but AIX uses SCSI ids for the robotics and the SCSI ids change when failover occurs causing a manual reconfigure of the devices to be necessary.
IBM AIX
NBU can rediscover devices after failback
See Radiance case #65525285