Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1018148.1 : Sun Fire[TM] Server: Problems Installing a DAT Drive in a V1280, Netra[TM] 1280 or E2900
PreviouslyPublishedAs 229498
Applies to:Sun Netra 1280 ServerSun Fire V1280 Server Sun Fire E2900 Server All Platforms Symptoms{SYMPTOM}After installation of a DDS4 DAT (Digital Audio Tape) drive into a Sun Fire[TM] V1280, Netra[TM] 1280 or E2900 server, the "clean" or "fault" LED (Light-Emitting Diode) remains "ON" permanently and the DAT drive cannot be used. Changes{CHANGE}Cause{CAUSE}SolutionResolutionTo install a DAT drive into a Sun Fire V1280, Netra 1280 or E2900 server, the installation engineer must first remove the filler panel that occupies the slot where the DAT drive is to be installed. The filler panel is made up of a base plate on which there is a metal frame that fills the hole, which is usually occupied by the front panel of a DAT drive. The installation engineer must unscrew the metal frame from the baseplate, discard the metal frame part, retain the base plate upon which to mount the DAT drive, and use the 4mm screws supplied in the box to mount the DAT drive on the baseplate. If the installation engineer uses the leftover screws from the disassembly of the filler panel, which are too long for the front mounting holes on the underside of the DAT drive, the "clean" or "fault" LED will come ON and remain ON. This is because the screws from the disassembled base plate are too long and make contact with a surface mount component on a PCB (Printed Circuit Board) inside the DAT drive. Solution: Use the pack of 4mm screws that come in the box with the DAT drive. Relief/Workaround If the installation engineer retains the filler panel screws, they should only be used in the back holes (underside) of the DAT drive. Additional Information At the time of writing this document, the part number of the pack of 4mm screws was not available. The label on the pack of screws reads as follows: "Screws For Sunfire V1280/Netra 1280 Only" However, you can safely use these screws when installing a DAT drive in a E2900 also. Product Sun Fire E2900 Server Sun Fire V1280 Server Netra 1280 Server Internal Comments This document is a Normalized Resolution Path and is managed by the MidRange Server Group's Domain Engineer. Please send any feedback on this resolution path to [email protected]. Include the document ID in the subject line. Do not update this document without first contacting the feedback email alias. v1280, e2900, Netra1280, dds4, dat, clean, fault, normalized Previously Published As 76806 Product_uuid 63ff680d-0598-11d8-84cb-080020a9ed93|Sun Fire E2900 Server 6a74b2f9-bbd8-4b2c-870d-b6b73d6e224f|Sun Fire V1280 Server e41a7084-3dbf-472d-918b-efb50dcbc220|Netra 1280 Server Attachments This solution has no attachment |
||||||||||||
|