Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1017291.1 : HP LTO3 - Drive Operates at Reduced Transfer Rate When Daisy Chained to SL500
PreviouslyPublishedAs 228262
Applies to:Sun StorageTek SL500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]HP LTO3 Tape Drive - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 9-Dec-2010. SymptomsSlow performanceB/47/03 0B/47/03 Backup runs slow Slow transfer rate Changes{CHANGE}CauseWith HP LTO3 drives daisy chained to a L500(SL500) library, the drives will negotiate to a lower transfer rate during write/read operation. In the var/adm/messages file you see "Target 3 reverting to async. mode".With HP LTO3 drives daisy chained to a L500(SL500) library, the drives will negotiate to a lower transfer rate during write/read operation. In the var/adm/messages file you see "Target 3 reverting to async. mode". On some occasions, commands are aborted. When this occurs, you will see "Sense Key: Aborted Command" with an ASC 0x47 ASCQ 0x3. OBx4703 is "Information Unit CRC error detected, the drive has detected a CRC error during the command IU or data out phase". This issue has also been seen when there are 3 or more HP LTO 3 drives on the same bus. SolutionWhen this issue occurs the typical messages file will look similar to the following:Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.warning] WARNING: /pci@7c0/pci@0/pci@1/pci@0,2/scsi@1 (mpt3): Aug 31 09:02:55 rss57 Target 3 reverting to async. mode Aug 31 09:02:55 rss57 mpt: [ID 675377 kern.warning] WARNING: ID[SUNWpd.mpt.sync_wide_backoff.6013] Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.warning] WARNING: /pci@7c0/pci@0/pci@1/pci@0,2/scsi@1/st@3,0 (st14): Aug 31 09:02:55 rss57 Error for Command: write Error Level: Fatal Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.notice] Requested Block: 0 Error Block: 0 Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.notice] Vendor: HP Serial Number: 13:40 rss57 genunix: [ID 936769 kern.notice] px_pci6 is /pci@7c0/pci@0 Aug 30 14:13:40 rss57 px_pci: [ID 37 Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.notice] Sense Key: Aborted Command Aug 31 09:02:55 rss57 scsi: [ID 107833 kern.notice] ASC: 0x47 (information unit iucrc error detected), ASCQ: 0x3, FRU: 0x013:40 rss57 px_pci: [ID 370704 kern.notice] PCI-device: pci@0,2, px_pci10 Corrective Action:
At this time, isolate the L500 SCSI controller on its own SCSI bus and do not daisy chain more that two HP LTO 3 drives together. HP LTO Gen 3, L500, SL500, Daisy chained drives, This is a design issue, audited Previously Published As STKKB78608 Attachments This solution has no attachment |
||||||||||||
|