Solution Type Problem Resolution Sure Solution 1016896.1 : SL8500 - Tray Cable Causing T10000 Link Errors
PreviouslyPublishedAs 227280 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential for Partners and Oracle Support personnel
Applies to:Sun StorageTek SL8500 Modular Library SystemSun StorageTek T10000 Tape Drive - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 3-Mar-2011. SymptomsLink errorPoor Link Performance Intermittent Communication error Changes{CHANGE}CauseBad cable in T10000 drive tray.SolutionResolutionReplace cable Additional Information SL8500 TRAY WITH INCORRECT FIBRE CABLES This tech tip concerns only SL8500 T10000 4 Gbit Fibre with 850nm Long-wave SFP transceivers. The effected CEI number is 3100276053. Some of these trays were built using the wrong fibre cable inside the tray. Trays with the wrong cable may experience Fibre link errors and degraded link performance. These trays can be identified WITHOUT removing them from the Library: 1) View drive tray from rear. Look through the ventilation holes and determine the color of the Fibre cable connector and strain relief. Verify you are looking inside the tray and not looking at the bulk-head Fibre LC adapter. 2) A blue connector/strain relief is BAD. 3) A white/tan connector is GOOD. Additional verification of the correct cable can be performed as follows: 1) Remove tray from Library. 2) Open top cover of tray. 3) The Correct Fibre cables should be orange colored with a PN 10800316. The installed SFP transceivers should 850 nm. 4) The Wrong Fibre cable is yellow with PN 10800339. This cable is only correct for use on long-wave 1310 Nm SFP transceivers.
@ Previously Published As STKKB79775 Attachments This solution has no attachment |
||||||||||||
|