Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1016849.1 : SL500 - Redundant Power Supply Turn Off in DEM, Result Code 8003
PreviouslyPublishedAs 227171
Applies to:Sun StorageTek SL500 Modular Library SystemAll Platforms SymptomsSymptomsLED on one of the power supplies will turn off and the service required LED will begin to Flash Power supply failure Power supply error in the log RC8003 Error 8003 Changes{CHANGE}CauseRedundant power supply installed in DEM When the voltage on the 3.3V line of the 2 supplies is far enough apart it can cause one of the supplies to be shut down All the RLE - PN 313907406 and older have been purged from stock.SolutionReplace RLE with PN 313907408 level or higher.Attachments This solution has no attachment |
||||||||||||
|