Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1016754.1
Update Date:2011-05-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  1016754.1 :   SVA - FSC79A5 - pfaelg4a.dat overflow due to High Volume of FSC3FFA errors  


Related Items
  • Sun StorageTek V2X SVA Disk System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
  •  

PreviouslyPublishedAs
226923


Applies to:

Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable - Release: N/A to N/A
All Platforms
Updated for currency 05/20/11

Symptoms


The PFAELG4A.DAT error log overflows is due to a high quantity of FSC3FFA errors on V2X and V2Xf.

Cause

The FSC3FFA entries in the PFAELG4A.CNT or PFAELG4B.CNT file are not errors - they are events and are not a problem.


Definition of FSC:
#define FSC3FFA_EST_PPRC_PAIR_NO_COPY_SUCCESSFUL 0x3FFA CSE: @SAME ENG: A PSF Establish PPRC Pair order that specified 'no copy' was received and completed successfully.

Solution

Resolution
To eliminate overflow:
1. VSM/SVA HW support needs to review PFAELG4A.CNT and PFAELG4B.CNT files to verify no indication of a problem.
Note: Specifically check for errors when pfaelg4a.dat file exceeded 5 MB and was renamed pfaelg4b.dat.

2. If entries are just informational, no action is required other than verify V2X or V2Xf box is at latest code levels.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.