Solution Type  Problem Resolution Sure

Solution  1016322.1 :   VTSS fails to initialize during HSC/VTCS start-up after SLS6675E with RC=08  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
225794


Symptoms
VTSS fails to initialize during HSC/VTCS start-up
Message SLS6675E occurs for one or more VTDs
Lack of SLS6632I "VTSS server ready" message for each VTSS
SLS6632I does not occur if only one VTSS is configured
Message SLS6670E may also be issued
SLS6675E VTSS:nnnnnnnn VTD:dddd CONFIGURATION ERROR RC=6A40FF0C
SLS6675E VTSS: nnnnnnnn VTD: dddd CONFIGURATION ERROR RC=00000008 SUBSYSTEM INFO: 99999999/mmmm/ooooooo
SLS6698I ECAM I/O ERROR ON VTD dddd

SLS6670E RTD rrrrrrrr FAILED INITIAL CONFIGURATION WITH CC=254 RC=0


Resolution
This problem generally occurs with a new install of a VTSS when the production arrays within the VTSS itself were not configured.

The CSE needs to configure the production arrays within the VTSS subsystem. After that has been completed, then stop and restart HSC/VTCS.

Product
Sun StorageTek VTCS
Sun StorageTek Virtual Storage Manager System

Internal Comments
The Knowledge Work Queue for this article is KNO-STO-MAINFRAME_LIB_MGMT_SW.

Tech Review history
Audited/updated 02/13/2010 - [[email protected]], Mainframe SW Content Team - validated still current, made minor changes to statement order