Applies to:Sun Storage Host Software Component (HSC) - Version: All VersionsSun Storage SL8500 Modular Library System - Version: Not Applicable and later [Release: NA and later] IBM z/OS on System z SymptomsSLS0660I error messages received every 5 minutes.SLS0660I ERR BCST - (01400114005C04) SLS0662I LMU Response error - xx,xxx,28,13 ChangesCauseThe 28,13 on the SLS0662I indicates Invalid Broadcast and Invalid LSM respectively. For the 'C04' at the end of the SLS0660I message, the 'C' indicates Open Door and the '04' is the LSM ID. This means HSC is receiving a broadcast from the LSM ID but HSC has no knowledge of an LSM with that number. The SLS0660I can be issued more than once with a different number at the end of the string to indicate a different LSM ID.SolutionThis problem needs to be investigated by the CSE from the hardware perspective. It is the hardware sending these broadcasts to HSC.For example, if there were two SL8500s connected but one was removed, verify that all cables and PTPs between the two SL8500s are disconnected. The problem may also be a config file in the SL8500 that needs to be cleared. The CSE should be able to do that or they can contact Tape Hardware Support for assistance. SL8500 microcode has also been a solution to this problem. Previously Published As STKKB79865 Product_uuid 817ba1d5-2831-4203-b6b0-c682df25a7d8 Attachments This solution has no attachment |
||||||||||||
|