Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015615.1
Update Date:2011-04-27
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015615.1 :   L700/180 - Atempo Time Navigator Not Supporting Auto Cleaning  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
224103


Applies to:

Sun StorageTek L180 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L700 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 27-Apr-2011.

Symptoms

Atempo Time Navigator not supporting auto cleaning
Unable to recognize Not Ready Sense Key when a cleaning cartridge is installed
Host receives data mount error for duration of tape cleaning time
2/30/03
2/04/00
2/04/01

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Additional Information
Atempo
Tape cleaning
L700
L180
Time Navigator
Refer to Pinnacle 819221 for complete details on this issue.

Resolution
The patch fixing the issue for cleaning tapes is patch #1440 in Time Navigator 3.703 or 3.704.

Previously Published As STKKB54257


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.