Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015472.1
Update Date:2011-05-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015472.1 :   L180/L700 - Swap of LTO Drives Causes Loss of Dynamic WWN  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • LTO Tape Drive
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Drives - LTO
  •  

PreviouslyPublishedAs
223776


Applies to:

LTO Tape Drive - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L700 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L1400 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L180 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 6-May-2011.

Symptoms

Customer unable to see drive after swapping.
Unable to see drive after replacement.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
Use REVERT command under CLI interface to reset the Drive WWNs to Native before swapping drives.
Refer to Document: 1013289.1 for further information on this issue.



L700 changed from Native WWN to Dynamic WWN, L700, Dynamic world wide name, LTO Ultrium, LTO Ultrium Generation 2, L700e, L180, dWWN, Moved drives between slots, Swapped drive position