Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1015472.1 : L180/L700 - Swap of LTO Drives Causes Loss of Dynamic WWN
PreviouslyPublishedAs 223776
Applies to:LTO Tape Drive - Version: Not Applicable and later [Release: N/A and later]Sun StorageTek L700 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 6-May-2011. SymptomsCustomer unable to see drive after swapping.Unable to see drive after replacement. Changes{CHANGE}Cause{CAUSE}SolutionResolutionUse REVERT command under CLI interface to reset the Drive WWNs to Native before swapping drives. Refer to Document: 1013289.1 L700 changed from Native WWN to Dynamic WWN, L700, Dynamic world wide name, LTO Ultrium, LTO Ultrium Generation 2, L700e, L180, dWWN, Moved drives between slots, Swapped drive position Previously Published As STKKB42426 Attachments This solution has no attachment |
||||||||||||
|