Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1015447.1 : L180/700/1400 - All Drives Positions in Drive Tower Report None Functional
PreviouslyPublishedAs 223727 Oracle Confidential (PARTNER). Do not distribute to customers Reason: Confidential information provided to Oracle and Partner Service Personnel
Applies to:Sun StorageTek L700 Tape LibrarySun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 2-Feb-2011. SymptomsFSC3E0BFSC3E0C Drives not functional Changes{CHANGE}Cause{CAUSE}SolutionResolutionAll Drives Positions in Drive Tower Report None Functional: 1. Re-ipl drive 2. Run diags on drives from library. 3. If drive is still not functional, move to tower 1 or to working slot if possible. 4. If re-ipling drive brings it online to L700 op panel, replace hand assembly. 5. It is possible to swap tower 0 connection on MPC card with tower 1. (Note: Drives must be brought online and ready for this to work) 6. Run diags from library: a. If tower connection 0 is still bad, replace MPC card. b. If tower 1 is bad, replace tower. L700, Drive Tower 0, DLT7000, Library Hand, downlevel, EC, does, not, initialize drives correctly, All, drives, positions, tower, online, host, being, seen, data, path, control path, DLT, DLT8000, DLT4000 Previously Published As STKKB13367 Attachments This solution has no attachment |
||||||||||||
|