Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1015263.1 : L700/L180 - Library fails Initialization with FSC3104
PreviouslyPublishedAs 223240
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L700 Tape Library Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 2-Feb-2011. SymptomsL700e fails initializationFSC3104 Hand failed to retract to safe position Changes{CHANGE}CauseDisplaced door magnet.SolutionResolutionCheck that the magnet has not fallen out of place on the door and the cable connection for the door interface is properly seated. L700, L180, Magnet on the door is not engaging to allow the library robotics to begin initialization, door, interface, cable, connection, disturb, upgrade, L700e, PTP, (Pass-thru-Port), L700e, All FRUs and cables did not resolve this problem, Refer, Clarify, case 1831765 for details of this problem, audited Previously Published As STKKB1203 Attachments This solution has no attachment |
||||||||||||
|