Solution Type  Problem Resolution Sure

Solution  1015263.1 :   L700/L180 - Library fails Initialization with FSC3104  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
223240


Applies to:

Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L1400 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 2-Feb-2011.

Symptoms

L700e fails initialization
FSC3104
Hand failed to retract to safe position

Changes

{CHANGE}

Cause

Displaced door magnet.

Solution

Resolution
Check that the magnet has not fallen out of place on the door and the cable connection for the door interface is properly seated.

L700, L180, Magnet on the door is not engaging to allow the library robotics to begin initialization, door, interface, cable, connection, disturb, upgrade, L700e, PTP, (Pass-thru-Port), L700e, All FRUs and cables did not resolve this problem, Refer, Clarify, case 1831765 for details of this problem, audited
Previously Published As STKKB1203

Attachments
This solution has no attachment