Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1015151.1 : VSM - Message SLS5079E mount failed CC=9 RC =146
PreviouslyPublishedAs 222977
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms SymptomsMessage SLS5079E received for VTV mountSLS5079E MOUNT OF vvvvvv ON dddd - FAILED (rc) - CC=9 RC=146 ECAM error CC=9 RC=146 in the SLS5079E message indicates 'No logical paths established'. CausePossible causes are:1. VTCS has the address defined in the CONFIG but it is not in the HCD. 2. The affected host does not have any paths to the VTSS that it is sending the ECAM message to. Solution1. Define VTCS address in HCD2. Establish paths to VTSS Previously Published As STKKB67794 Attachments This solution has no attachment |
||||||||||||
|