Solution Type  Problem Resolution Sure

Solution  1015151.1 :   VSM - Message SLS5079E mount failed CC=9 RC =146  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
222977


Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
All Platforms

Symptoms

Message SLS5079E received for VTV mount
SLS5079E MOUNT OF vvvvvv ON dddd - FAILED (rc) - CC=9 RC=146

ECAM error CC=9 RC=146 in the SLS5079E message indicates 'No logical paths established'.

Cause

Possible causes are:

1. VTCS has the address defined in the CONFIG but it is not in the HCD.
2. The affected host does not have any paths to the VTSS that it is sending the ECAM message to.

Solution

1. Define VTCS address in HCD
2. Establish paths to VTSS