Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015066.1
Update Date:2011-02-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015066.1 :   SL8500 - H-Bot Code Does Not Upgrade on Replacement H-bot  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
222787


Applies to:

Sun StorageTek SL8500 Modular Library System
All Platforms
Checked for relevance on 9-Feb-2011.

Symptoms

Code does not upgrade on replacement h-bot.
Code is downlevel on replacement robot.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
H-bot Code Does Not Upgrade on Replacement H-bot.
1. Vary LSM for affected rail offline on ACSLS or HSC.

 

2. From Utilities menu on SLC choose the Activate tab.

3. Select current SL8500 code level.

4. Apply.

5. Select Cancel from Reboot message.

6. On the same screen High light the robot needing upgrade and press Reboot OR power cycle the rail for the replaced H-bot by the circuit breaker on the HBS card for that rail.

7. Verify the H-bot code level on the System Details menu under properties tab of the replaced robot.




SL8500, Robot, H-bot, Sbot, Hbot, S-bot
Previously Published As STKKB51821