Solution Type Problem Resolution Sure Solution 1014835.1 : L180/700/1400 - FSC3381 - Will Not Pass Calibration
PreviouslyPublishedAs 222239
Applies to:Sun StorageTek L180 Tape LibrarySun StorageTek L700 Tape Library Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance 2-Feb-2011. SymptomsUnable to complete audit at reserve cell areaUnreadable target Library audit fails FSC3381 FSC3329 FSC3311 Target fell apart but it has a fine crack that was not seen by visual inspection Problem occurred with multiple library firmware levels FSCs were posted excessively, not just a couple failures Changes{CHANGE}Cause{CAUSE}SolutionResolutionReplace cracked calibration target This part must be ordered by the Customer Service Representative. @ New library install, L700, L180 Previously Published As STKKB24605 Attachments This solution has no attachment |
||||||||||||
|