Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1014805.1 : VSM - MVCs Incorrectly Identified As Expired
PreviouslyPublishedAs 222147 Symptoms MVCs are incorrectly identified as expired Resolution Install the following microcode level for the appropriate device type:
Note: There is no problem applying the PTFs when running a microcode level released prior to the bad code. For example, the PTFs can be applied when using 9840A RTDs at level 1.28. Additional Information VTCS 4.0 VTCS 5.0 9840B devices are not affected. PTF L1H10S3 (SWS4000) PTF L1H10S2 (SWS4100) PTF L1H10XO (SWS5000) 9940A Microcode 1.30.210 9940A Microcode 1.30.211 9840A Microcode 1.30.110 9840A Microcode 1.30.111 The PTFs listed (L1H10S3, L1H10S2, L1H10X0) introduced checking of the status of the physical tape when performing operations on the MVC as returned by the drive.
Product VSM Previously Published As STKKB4303 Product_uuid 5178b7a4-cfef-11da-a933-080020a9ed93 Attachments This solution has no attachment |
||||||||||||
|